Bear Medical
Bear 750vsBear Cub 750 pvs also available
Offers assist/control, SIMV/IMV/CPAP, and integrated
sychronized ventilation and tidal volume monitoring.
|
 |
Bird Products
Bird V.I.P.
Microprocessor ventilator for infants and pediatrics.
offers assist/control and SIMV/CPAP in both Volume
cycled and Time cycled modes. (pictured with a Partner
IIi monitor)
|
 |
Bird Products
Bird VIP Gold
Offers assist/control, SIMV/IMV/CPAP, and integrated
sychronized ventilation and tidal volume monitoring.
|
 |
Bird Products
Bird Graphic Monitor
Option offering real-time waveforms for pressure,
flow and volume as well as flow and pressure volume
loops. Trends ten(10) different parameters.
|
 |
Drager
Drager Babylog
Microprocessor infant ventilator.
Offers SIMV, assist control PEEP/CPAP and VIVE(variable
expiritory flow). Built in graphics display of waveform.
|
 |
Nellcor Puritan Bennett
840 (if equipped with neo-mode)
Compact critical care ventilator offering advance
design to provide ventilatory support to neonates
through adults. Comprehensive array of modulation
including Bilevel. Extensive monitoring and alarm
protection.
|
 |
Sechrist
IV-100B
Microprocessor time cycled, pressure limited infant
ventilator. Offers CMV, IMV and CPAP modes. Includes
air/oxygen mixer and exhalation valve.
|
 |
Sensormedics 3100A Oscillatory
Ventilator
Electronic-power,
electronically controlled oscillatory lung ventilator.
Its 365cc oscillating driver is a diaphragmatically
sealed piston with adjustable displacement, frequency
and I:E ratio, which produces 3-15 Hz pressure
waves superimposed on an adjustable level of positive
mean airway pressure. It distinguises itself form
other types of High Frequency ventilators by its
active expiratory phase. |
 |
Sechrist
IV-200 SAVI
Redesigned infant ventilator incorporating SAVI
electronic trigger system and electronic manometer.
|
 |
Sechrist
Millennium
From Sechrist Industries comes the MillenniumTM
- the infant/pediatric ventilator for the next century.
Designed for maximum performance and user-friendly
convenience, for which Sechrist has always been
known. The MillenniumTM combines state-of-the-art
electronics with the simplicity of pressure sensing
technology.
The result?
Simple, reliable ventilation for all your neonatal,
infant, and pediatric patients.
|
State of the art electronics using
pressure sensing technology for synchronizing the
ventilator with the patients breathing cycle. Apnea
back up ventilation available in CPAP mode. Neonatal,
infant and pediatric applications.
SYNCHRONIZATION FOR EVEN THE SMALLEST CHILD.
What sets the MillenniumTM apart is the patent pending
SmartSyncTM, a unique pressure sensing device that
synchronizes the patient’s natural breathing
cycle with the ventilator. It has a maximum sensitivity
of 0.50 cmH2O, and a response time of 5-40 milliseconds
depending upon the sensitivity setting. With this
technology from a company you’ve known and
trusted for decades, you can be certain the MillenniumTM
will provide your patients with unparalleled performance.
The SmartSync TM weighs only 5 grams, and adds only
1.5cc of mechanical dead space. Convenient, single-patient
use meets your infection control needs and assures
accurate synchronous triggering every time.
FAST, SIMPLE MESSAGES AND ALARMS FOR QUICK, DECISIVE
ACTION.
The MillenniumTM provides a continuous display of
peak pressure, PEEP, mean airway pressure, measured/set
respiratory rate, and breath status in graphic and/or
digital displays.
And when action is required, the LCD message window
offers a brief description of the situation,enabling
the clinician to take quick, decisive action. The
alarm mute feature enables patients to remain undisturbed
while corrections and adjustments are made.
Intuitive controls are simple to set-up and operate,
an especially valuable feature when the situation
needs immediate attention. Manual breath option
is electronically controlled to deliver precise
breaths according to the desired setting. Lightweight,
compact design (21 lbs.9.5/kg.) with built-in handle
for added convenience.
|